This is an old revision of the document!
source TriDAS_r45/pixel/POSRelease/setenv.sh
cd TriDAS_r45/pixel/PixelRun ./run.sh --xml auto - Start testing with POS (see below)
source TriDAS_r45/pixel/POSRelease/setenv.sh cd TriDAS_r45/pixel/PixelRun ./run.sh --xml auto
go to http://cmspixel2.psi.ch:1973/ click on "PixelSupervisor" click "Initialize" select calibration to run click "Configure" check that FED phases have been found click "Start" Once the calibration finished. Look at the results in: cd TriDAS_r45/pixel/PixelRun/Runs/Run_0/Run_yourrunnr
Keep track of your results by entering them in this elog: (user and password are the same as to access testing PC). https://elog.physik.uzh.ch:8080/PixelPOS/ Enter sector, run number and calibration and additional information if needed.