Line 11: | Line 11: | ||
* Optical fibers (tkFEC, pxFEC, FED 1-5) | * Optical fibers (tkFEC, pxFEC, FED 1-5) | ||
- Verify that cooling sytem is running | - Verify that cooling sytem is running | ||
- | * Linke to Malte' | + | * See Malte' |
- Verify that temperature and humidity reading are as expected | - Verify that temperature and humidity reading are as expected | ||
- Power on CCU and opto power | - Power on CCU and opto power | ||
* CCU: 2.5V (expected current about 1.4A) [Slot 9 CCU] | * CCU: 2.5V (expected current about 1.4A) [Slot 9 CCU] | ||
* Opto: 2.5V (expected current about 3A per sector) [Slot 7 OPTO 1,2,3,4 for S4,3,2,1 (upper cable), for S5,6,7,8 (lower cable)] | * Opto: 2.5V (expected current about 3A per sector) [Slot 7 OPTO 1,2,3,4 for S4,3,2,1 (upper cable), for S5,6,7,8 (lower cable)] | ||
+ | - Check CCU ring and ST i2c communication using BPixelTools | ||
- Power on module: | - Power on module: | ||
* Top: L14 | * Top: L14 | ||
* Bottom: L23 | * Bottom: L23 | ||
- | - Start POS | + | - Start testing with POS (see How to run POS) |
+ | |||
+ | ===== How to run BPixelTools ===== | ||
+ | |||
+ | source TriDAS/ | ||
+ | cd TriDAS/ | ||
+ | ./run.bsh | ||
+ | |||
+ | scanccu | ||
+ | FEC 0x0 Ring 0x0 CCU 0x7e found | ||
+ | FEC 0x0 Ring 0x0 CCU 0x7d found | ||
+ | FEC 0x0 Ring 0x0 CCU 0x7c found | ||
+ | FEC 0x0 Ring 0x0 CCU 0x7b found | ||
+ | FEC 0x0 Ring 0x0 CCU 0x7a found | ||
+ | FEC 0x0 Ring 0x0 CCU 0x79 found | ||
+ | FEC 0x0 Ring 0x0 CCU 0x78 found | ||
+ | FEC 0x0 Ring 0x0 CCU 0x77 found | ||
+ | |||
+ | scanringedevice | ||
+ | prints list of all i2c devices | ||
+ | |||
+ | * If you do not see the expected output, try to powercycle the CCU and opto power. | ||
+ | * If scanringedevice crashes, try to disconnect and reconnect the fibers going to the TKFEC. | ||
===== How to run POS ===== | ===== How to run POS ===== | ||
Line 39: | Line 63: | ||
cd TriDAS_r45/ | cd TriDAS_r45/ | ||
| | ||
+ | | ||
+ | === How to analyze PixelAlive === | ||
+ | | ||
+ | $BUILD_HOME/ | ||
+ | | ||
+ | | ||
+ | ===== List of Calibrations ===== | ||
+ | |||
+ | POHBias | ||
+ | TBMDelay25 | ||
+ | TBMDelayBPIX | ||
+ | VcthrCalDel | ||
+ | ROCDelayBPIX | ||
+ | IanaBPIX | ||
+ | PixelAlive | ||
+ | | ||
+ | ===== How to go to the next sector ===== | ||
+ | - Connect module power and fibers | ||
+ | - Change POS configuration files to appropriate sector | ||
+ | |||
+ | cd TriDAS_r45/ | ||
+ | cd detconfig/ | ||
+ | cp detectconfig.dat_sector detconfig.dat | ||
+ | cd ../ | ||
+ | cp translation.dat_sector translation.dat | ||
+ | cd ../ | ||
+ | cp portcardmap.dat_sector portcardmap.dat | ||
| | ||
===== Elog ===== | ===== Elog ===== | ||
Line 46: | Line 97: | ||
https:// | https:// | ||
| | ||
- | | + | |
+ | * For each sector, enter a summary of working/ | ||
+ | |||
+ | ===== How to start up temperature sensor reading ===== | ||
+ | |||
+ | Login to the PC: user: PC7530\cms, password: Pixel2017 | ||
+ | |||
+ | Start LabView2015 | ||
+ | Select project TempReadout | ||
+ | Open file TempReadout_pc.vi | ||
+ | Click play in the upper left corner | ||
+ | |||
+ | Before exiting the program, click stop in the upper right corner! | ||