User Tools

Site Tools


phase1:phase1:remoteconnection

How to start the setup from remote

  • Ask someone to switch on CRATE and power supply
  • ssh to the cmspixel computer (only from uzh internal linux cluster)
ssh -XY cmspixel@cmspixel
password: uzh2014
  • start the CAEN and power on the components
 telnet 172.19.4.176 1527
 username: user
 password: user
 
 Main --> Channels
 Enable (last column to the right) and power on CH0011 and CH0013 for CCU and POH motherboard
 Power on CH0006 and CH0001 for the modules
  • run a quick check that everything is connected and powered
cd ~/TriDAS/pixel/BPixelTools/ccu/
source setup.bsh
./run.bsh
  • if everything is fine you will get this result
FEC 0x15 Ring 0x8 CCU 0x7e found
FEC 0x15 Ring 0x8 CCU 0x7d found
FEC 0x15 Ring 0x8 CCU 0x7c found
FEC 0x15 Ring 0x8 CCU 0x7b found
FEC 0x15 Ring 0x8 CCU 0x7a found
FEC 0x15 Ring 0x8 CCU 0x79 found
FEC 0x15 Ring 0x8 CCU 0x78 found
FEC 0x15 Ring 0x8 CCU 0x77 found
  
phase1/phase1/remoteconnection.txt · Last modified: 2016/08/26 12:17 by ngadiuba