tct_setup
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| tct_setup [2024/11/21 14:36] – [Table] vagelis | tct_setup [2024/12/11 21:40] (current) – [Software] prezae | ||
|---|---|---|---|
| Line 16: | Line 16: | ||
| | Control PC | Advantech MIC-770 | | Control PC | Advantech MIC-770 | ||
| | Oscilloscope | | Oscilloscope | ||
| - | | ::: | ::: | ::: | ::: | LCRYADMIN | + | | ::: | ::: | ::: | ::: | LCRYADMIN |
| | Low voltage power supply | | Low voltage power supply | ||
| | High voltage power supply | | High voltage power supply | ||
| Line 27: | Line 27: | ||
| The TCT computer has a public key used to access the distributed storage for data migration. The key is located at / | The TCT computer has a public key used to access the distributed storage for data migration. The key is located at / | ||
| From a bash command prompt one can simply type: **//ssh UZHServer// | From a bash command prompt one can simply type: **//ssh UZHServer// | ||
| + | |||
| + | The allocated storage at / | ||
| + | |||
| + | To copy pre-existing data to the server please use: | ||
| + | rsync -avh --progress <current data folder> / | ||
| + | This will endure recursive directory copy and will validate files while displaying progress of the operation. | ||
| The optics used in the UZH setup and their specifications can be found in the following table. | The optics used in the UZH setup and their specifications can be found in the following table. | ||
| Line 74: | Line 80: | ||
| - Manually locate the four corners by adjusting the position of the sensor using the software. Increasing the position in the positive x-direction shifts the plate towards the right side of the box, and increasing the position in the positive y-direction shifts the plate towards the back of the box. Once at the corner of an active region, the observed waveform amplitude will decrease and totally disappear. | - Manually locate the four corners by adjusting the position of the sensor using the software. Increasing the position in the positive x-direction shifts the plate towards the right side of the box, and increasing the position in the positive y-direction shifts the plate towards the back of the box. Once at the corner of an active region, the observed waveform amplitude will decrease and totally disappear. | ||
| - Once the four corners have been located, shine the laser somewhere in the middle of one of the four quadrants. There is a macro script to run which adjusts the z position (height) of the laser while measuring the voltage. Using this, we can find out the optimum distance the laser should be from the sensor. | - Once the four corners have been located, shine the laser somewhere in the middle of one of the four quadrants. There is a macro script to run which adjusts the z position (height) of the laser while measuring the voltage. Using this, we can find out the optimum distance the laser should be from the sensor. | ||
| + | - Alternatively, | ||
| + | - {{ prosedure_1.png? | ||
| ==== Trigger ==== | ==== Trigger ==== | ||
| Line 90: | Line 98: | ||
| To run the script, enter the following command into the terminal: | To run the script, enter the following command into the terminal: | ||
| python3 TheSetup.py | python3 TheSetup.py | ||
| - | Next, to access the graphical interface of the motors, locate the script " | + | To access the graphical interface of the motors, locate the script " |
| code/ | code/ | ||
| Then, enter the following command into the terminal to run the script: | Then, enter the following command into the terminal to run the script: | ||
tct_setup.1732196188.txt.gz · Last modified: by vagelis