User Tools

Site Tools


psi:psi

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Next revisionBoth sides next revision
psi:psi [2017/01/11 21:12] – [Testing procedure] leacpsi:psi [2017/01/12 18:07] – [How to run POS] leac
Line 63: Line 63:
   cd TriDAS_r45/pixel/PixelRun/Runs/Run_0/Run_yourrunnr   cd TriDAS_r45/pixel/PixelRun/Runs/Run_0/Run_yourrunnr
      
 +  
 +=== How to analyze PixelAlive === 
 +  
 +  $BUILD_HOME/pixel/PixelAnalysisTools/test/bin/linux/x86_64_slc6/PixelAnalysis.exe $BUILD_HOME/pixel/PixelAnalysisTools/test/configuration/PixelAliveAnalysis.xml yourrunnur
 +  
 +Edit xml file to include the FEDs of interest.  
 +===== List of Calibrations =====   
 +
 +  POHBias
 +  TBMDelay25
 +  TBMDelayBPIX
 +  VcthrCalDel
 +  ROCDelayBPIX
 +  IanaBPIX
 +  PixelAlive
 +  
 +===== How to go to the next sector ===== 
 +  - Connect module power and fibers
 +  - Change POS configuration files to appropriate sector
 +
 +  cd TriDAS_r45/pixel/config
 +  cd detconfig/1/
 +  cp detectconfig.dat_sector detconfig.dat
 +  cd ../../nametranslation/1/
 +  cp translation.dat_sector translation.dat
 +  cd ../../portcardmap/1/
 +  cp portcardmap.dat_sector portcardmap.dat
      
 ===== Elog =====   ===== Elog =====  
Line 72: Line 99:
   *   For each calibration: enter sector, run number and calibration type and additional information if needed.   *   For each calibration: enter sector, run number and calibration type and additional information if needed.
   *   For each sector, enter a summary of working/non-working components.    *   For each sector, enter a summary of working/non-working components. 
 +
 +===== How to start up temperature sensor reading =====  
 +
 +Login to the PC: user: PC7530\cms, password: Pixel2017
 +  
 +  Start LabView2015
 +  Select project TempReadout
 +  Open file TempReadout_pc.vi
 +  Click play in the upper left corner
 +  
 +  Before exiting the program, click stop in the upper right corner!
 ===== mTCA specifics ===== ===== mTCA specifics =====
   * To load firmware after power cycle of the crate see: https://wiki.physik.uzh.ch/cms/phase1:phase1:mtcafull   * To load firmware after power cycle of the crate see: https://wiki.physik.uzh.ch/cms/phase1:phase1:mtcafull
psi/psi.txt · Last modified: 2017/01/17 11:48 by leac