This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
phase2:different_scenarios [2015/01/27 16:58] – cgalloni | phase2:different_scenarios [2015/01/27 17:23] (current) – dsalerno | ||
---|---|---|---|
Line 1: | Line 1: | ||
- | Different | + | Different |
- | We bin our measurement in 4 pt region: 1 Gev,2 GeV, 5GeV ,20 GeV. | + | We bin our measurement in 4 pt regions: 1 Gev, 2 GeV, 5GeV, 20 GeV. |
- | And we consider 3 eta region: C ( eta< 0.8), I (eta< 1.6), F (eta< | + | And we consider 3 eta regions: C ( eta< 0.8), I (eta< 1.6), F (eta< |
We use different scenarios: | We use different scenarios: | ||
Line 14: | Line 14: | ||
* TP with better resolution (7um x 15 um) sensors in first layer. | * TP with better resolution (7um x 15 um) sensors in first layer. | ||
- | * TP with better resolution (7um x 15 um) sensors in first layer (sensor thickness = 0.225 in the first Layer). [ If the pixel size is decrezed | + | * TP with better resolution (7um x 15 um) sensors in first layer (sensor thickness = 0.225 in the first Layer). [ If the pixel size is decreased |
- | * TP with better resolution (7um x 15 um) sensors in first layer, increasing material of the first layer [ the better resolution pixel has an area that is half compared to the Run I pixel. So in the same detector there will be a double number of pixel and an increase of the material, especially for the read-out]. | + | * TP with better resolution (7um x 15 um) sensors in first layer, increasing material of the first layer [ the better resolution pixel has an area that is half compared to the Run I pixel. So in the same detector there will be a double number of pixels |
* TP with better resolution (7um x 15 um) sensors in all 4 layers, (pixel thickness =0.225 in all Layers). | * TP with better resolution (7um x 15 um) sensors in all 4 layers, (pixel thickness =0.225 in all Layers). | ||
* TP with better resolution (7um x 15 um) sensors in all 4 layers, increasing material in all layers. | * TP with better resolution (7um x 15 um) sensors in all 4 layers, increasing material in all layers. | ||
+ | |||
- | * Strawman5 configuration is expalind | + | * Strawman5 configuration is explained |
+ | * Strawman5, with better resolution (7um x 15 um) sensors in 2 innermost ( and extension ) layers, Phase I resolution (13 um x 28 um) sensors in 2 outer layers. | ||
- | * Strawman5, with better resolution (7um x 15 um) sensors in 2 innermost ( and extension ) layers, Phase I resolution (13 um x 28 um) sensors in 2 layers. | + | * Strawman5, with better resolution (7um x 15 um) sensors in 2 innermost ( and extension ) layers, Phase I resolution (13 um x 28 um) sensors in 2 outer layers, (pixel thickness =0.225 in 2 layers). |
- | * Strawman5, with better resolution (7um x 15 um) sensors in 2 innermost ( and extension ) layers, Phase I resolution (13 um x 28 um) sensors in 2 layers, (pixel thickness =0.225 in 2 layers). | + | |
* TP with the number of pixels quadrupled. [Just to test] | * TP with the number of pixels quadrupled. [Just to test] | ||
+ | |||
+ | The results are reported in the tables: [[file:/// | ||