phase2:different_scenarios [2015/01/27 16:57] cgalloniphase2:different_scenarios [2015/01/27 17:01] cgalloni
Line 6: Line 6:
 We use different scenarios: We use different scenarios:
  
-TP- Technical Proposal: 4 Layers for the BP with pixel with the same resolution as the Run I in Phase I (13 um x 28 um); sensor: 100 um x 150 um, thickness T=0.3 mm ; innermost layer at 3 cm from the beampipe and the outermost layer 16.1 cm.+  * TP- Technical Proposal: 4 Layers for the BP with pixel with the same resolution as the Run I in Phase I (13 um x 28 um); sensor: 100 um x 150 um, thickness T=0.3 mm ; innermost layer at 3 cm from the beampipe and the outermost layer 16.1 cm.
  
-TP with outer layer at 18.8 cm.+  * TP with outer layer at 18.8 cm
 +  
 +  * TP but  one layer (the 3rd one at radius=10.9 cm) removed. 
 +  
 +  * TP with better resolution (7um x 15 um) sensors in first layer.  
 +  
 +  * TP with better resolution (7um x 15 um) sensors in first layer (sensor thickness = 0.225 in the first Layer). [ If the pixel size is decrezed 75 um x 100 um, to have the same charge sharing between pixel that we have in the Run I, the thickness shoud be reduced] 
 +  
 +  * TP with better resolution (7um x 15 um) sensors in first layer, increasing material of the first layer [ the better resolution pixel has an area that is half compared to the Run I pixel. So in the same detector there will be a double number of pixel and an increase of the material, especially for the read-out]. 
 +  
 +  * TP with better resolution (7um x 15 um) sensors in all 4 layers, (pixel thickness =0.225 in all Layers). 
 +  
 +  * TP with better resolution (7um x 15 um) sensors in all 4 layers, increasing material in all layers.
  
-TP but  one layer (the 3rd one at radius=10.9 cmremoved.+  
 +  * Strawman5 configuration is expalind in [[https://test-lantonel-tklayout.web.cern.ch/test-lantonel-tklayout/Strawman_5/indexpixel.html]] (with material changes in the tracker, and the reference  resolution of 10 um x 15 um).
  
-TP with better resolution (7um x 15 um) sensors in first layer+  * Strawman5, with better resolution (7um x 15 um) sensors in 2 innermost ( and extension ) layers, Phase I resolution (13 um x 28 um) sensors in 2 layers.
  
-TP with better resolution (7um x 15 um) sensors in first layer (sensor thickness = 0.225 in the first Layer). [ If the pixel size is decrezed 75 um x 100 um, to have the same charge sharing between pixel that we have in the Run I, the thickness shoud be reduced]+  * Strawman5, with better resolution (7um x 15 um) sensors in 2 innermost and extension ) layers, Phase I resolution (13 um x 28 um) sensors in 2 layers, (pixel thickness =0.225 in 2 layers). 
 +  
 +  * TP with the number of pixels quadrupled. [Just to test]
  
-TP with better resolution (7um x 15 um) sensors in first layer, increasing material of the first layer [ the better resolution pixel has an area that is half compared to the Run I pixel. So in the same detector there will be a double number of pixel and an increase of the material, especially for the read-out]. +The results are reported in the tables: [[file:///Users/cgalloni/Phase2Upgrade/tklayout/TechnicalProposal2014_Just3Layers/index.html]]
- +
-TP with better resolution (7um x 15 um) sensors in all 4 layers, (pixel thickness =0.225 in all Layers). +
- +
-TP with better resolution (7um x 15 um) sensors in all 4 layers, increasing material in all layers. +
- +
-Strawman5 configuration is expalind in  +
-[[https://test-lantonel-tklayout.web.cern.ch/test-lantonel-tklayout/Strawman_5/indexpixel.html]+
-(with material changes in the tracker, and the reference  resolution of 10 um x 15 um). +
- +
- +
-Strawman5, with better resolution (7um x 15 um) sensors in 2 innermost ( and extension ) layers, Phase I resolution (13 um x 28 um) sensors in 2 layers. +
-Strawman5, with better resolution (7um x 15 um) sensors in 2 innermost ( and extension ) layers, Phase I resolution (13 um x 28 um) sensors in 2 layers, (pixel thickness =0.225 in 2 layers). +
- +
-TP with the number of pixels quadrupled. [Just to test]+
  
phase2/different_scenarios.txt · Last modified: 2015/01/27 17:23 by dsalerno