 Different configuration of the Pixel Detector have been studied to determine which one would be the best to have a good resolution for pt and impact parameters for tracks. For the tracks we are interested in the pt range compatible with the one of tracks coming from a b-hadron decay (pt~ 3.5 GeV).  Different configuration of the Pixel Detector have been studied to determine which one would be the best to have a good resolution for pt and impact parameters for tracks. For the tracks we are interested in the pt range compatible with the one of tracks coming from a b-hadron decay (pt~ 3.5 GeV). 
 +
 We bin our measurement in 4 pt region: 1 Gev,2 GeV, 5GeV ,20 GeV. We bin our measurement in 4 pt region: 1 Gev,2 GeV, 5GeV ,20 GeV.
-And we consider +And we consider 3 eta region: C ( eta< 0.8), I (eta< 1.6), F (eta<2.4). 
 + 
 +We use different scenarios: 
 + 
 +  * TP- Technical Proposal: 4 Layers for the BP with pixel with the same resolution as the Run I in Phase I (13 um x 28 um); sensor: 100 um x 150 um, thickness T=0.3 mm ; innermost layer at 3 cm from the beampipe and the outermost layer 16.1 cm. 
 + 
 +  * TP with outer layer at 18.8 cm. 
 +  
 +  * TP but  one layer (the 3rd one at radius=10.9 cm) removed. 
 +  
 +  * TP with better resolution (7um x 15 um) sensors in first layer.  
 +  
 +  * TP with better resolution (7um x 15 um) sensors in first layer (sensor thickness = 0.225 in the first Layer). [ If the pixel size is decrezed 75 um x 100 um, to have the same charge sharing between pixel that we have in the Run I, the thickness shoud be reduced] 
 +  
 +  * TP with better resolution (7um x 15 um) sensors in first layer, increasing material of the first layer [ the better resolution pixel has an area that is half compared to the Run I pixel. So in the same detector there will be a double number of pixel and an increase of the material, especially for the read-out]. 
 +  
 +  * TP with better resolution (7um x 15 um) sensors in all 4 layers, (pixel thickness =0.225 in all Layers). 
 +  
 +  * TP with better resolution (7um x 15 um) sensors in all 4 layers, increasing material in all layers. 
 + 
 +  
 +  * Strawman5 configuration is expalind in [[https://test-lantonel-tklayout.web.cern.ch/test-lantonel-tklayout/Strawman_5/indexpixel.html]] (with material changes in the tracker, and the reference  resolution of 10 um x 15 um). 
 + 
 +  * Strawman5, with better resolution (7um x 15 um) sensors in 2 innermost ( and extension ) layers, Phase I resolution (13 um x 28 um) sensors in 2 layers.
  
 +  * Strawman5, with better resolution (7um x 15 um) sensors in 2 innermost ( and extension ) layers, Phase I resolution (13 um x 28 um) sensors in 2 layers, (pixel thickness =0.225 in 2 layers).
 + 
 +  * TP with the number of pixels quadrupled. [Just to test]
  
 +The results are reported in the tables: [[file:///Users/cgalloni/Phase2Upgrade/tklayout/TechnicalProposal2014_Just3Layers/index.html]]
  