=== Summary === - Checked the trigger efficiency with our selection (''abs(dijet_deta)<1.2 && abs(jet1_eta)<2.5 && abs(jet2_eta)<2.5 && jet1_pt>90 && jet2_pt>45 && dijet_mass>100 && PassJSON && isr_pt > 50 && HLT_CaloJet40_CaloScouting_PFScouting && run<=280385 && run>=277991'') and for ''HLT_CaloScoutingHT250'' trigger using the Calo Commissioning samples. At the left - trigger efficiency from AN and at the right - the trigger efficiency using our selection and ''HLT_CaloScoutingHT250'' trigger.{{ :users:danyyl:dijet:trig_eff_to_compare_with_an_our_sel.jpg?nolink&420|}}{{:users:danyyl:dijet:trig_eff_an.jpg?nolink&410|}} - We are interested in the range 200-600 GeV. Plot below shows the trigger efficiency from ~200 to ~700 GeV. The trigger efficiency reaches 100% after 260 GeV.{{:users:danyyl:dijet:trig_eff_200_700gev.jpg?nolink|}}